Mounting the Access Point
Mount the access point using the following user-provided hardware:
Step 4
Wooden structure—three 1/4 x 1 inch (minimum) lag bolts
Hollow walls—three 1/4-20 x 2 3/4 molly anchors
Concrete structure—three 1/4 x 1 inch (minimum) bolts with concrete anchors
Note
Tighten the bolts to secure the access point mounting bracket to the wall or ceiling.
Step 5
Mounting the Power Injector on the Access Point
When using the wall or ceiling mounting bracket, you can mount the power injector directly on the
access point mounting lugs (see
When mounted together, the access point and power injector must be mounted in a sheltered indoor
Note
environment.
Figure 3
Cisco Aironet 1300 Series Lightweight Outdoor Access Point Mounting Instructions
16
Examine the structure to ensure that the mounting location is not deteriorating or weak. You are
responsible for ensuring that the mounting location can adequately support the access point.
Figure
Mounting the Power Injector on the Access Point
3) using the hardware included with the bracket.
78-17634-01B0