First turn the switch of the target group, then push the
joystick to operate the liftouts of the selected group:
Liftout Up – Raise Liftouts
Liftout Down – Lower Liftouts
NOTE
In case the computer or the motion control system is down, liftouts
can still function from the gantry operator console using the
group selection switches and the joystick. The group select
switches identify groups per last active setup.
NOTE
Only one group activate a liftout at any given moment.
NOTE
On systems with more than one gantry head, only one operator
may activate liftouts at any given time. Communicate with the
other gantry operator so that liftouts are not activated
simultaneously.
5. Calibration
To calibrate an axis, follow the steps below:
Step 1. Click Tools on the Main Screen to open the
Maintenance Screen (Section 3.10)
Step 2. Select the axis that needs calibration
(Section 3.10)
Step 3. Click Prepare for Calibration. (Figure 60)
Figure 60
Step 4. Use the manual jog switch (Figure 61) of the
selected axis to move the puck to the desired
location. Selected puck will move in supper
slow speed when jog switch is activated
Never use a powered tool to turn the bolt and acme rod.
The high RPM generated by using a power tool will cause the
servo motor to generate back current.
This back current will cause the servo drive to fail.
Scribe marks (figure 62) are created during the installation after
the initial calibration. These marks can be used to calibrate a puck
to the initial calibration position if it loses calibration.
Step 5. Click Set Calibrate on the Maintenance Screen.
27
AutoSet Plus
P R O D U C T M A N UA L
NOTICE
NOTE
Figure 61
Scribe Marks
Figure 62
EN