15.2.9 Environment
For indoors and outdoors installation
Operating temperature
• Version with 24Vac or 24Vdc power supply: from
-40°C (-40°F) up to +65°C (149°F)
• Version with PoE+ power supply: from -40°C
(-40°F) up to +60°C (140°F)
• Temperature test complies with NEMA-TS 2-2003
(R2008) par. 2.1.5.1, test profile fig. 2-1 (from -34°C
(-29.2°F) to +74°C (165.2°F))
Surge immunity: up to 1kV line to line, up to 2kV line
to earth (Class 3)
Relative humidity: from 5% up to 95%
15.2.10 Certifications
Electrical safety (CE): EN60950-1, IEC60950-1,
EN62368-1, IEC62368-1
Electromagnetic compatibility (CE): EN61000-6-4,
EN50130-4, EN55032 (Class A), FCC Part 15 (Class A),
ICES003
Outdoor installation (CE): EN60950-22, IEC60950-22
IP protection degree (EN60529): IP66, IP67, IP68 (2h30
min, 2m (6.56ft)), IP69
UL certification: cULus Listed, TYPE 4X, TYPE 6P
EAC certification
MNVCNVX_2110_EN
15.2.11 Certifications - Railway
applications
Compliance to railway application standard:
EN50121-4 (only with 24Vac or 24Vdc power supply)
15.2.12 Certifications - Marine
applications
Lloyd's Register Marine Type Approval
• Test Specification Number 1 (ENV1, ENV2, ENV3,
ENV5)
Electromagnetic compatibility: EN60945
Salty fog resistance: EN60068-2-52
Tested at 70°C (158°F) for 16 hours in compliance with
EN60068-2-2
35