8 Installation

CAUTION! The electrical system to which the
unit is connected must be equipped with a
10A max automatic bipolar circuit breaker.
The minimum distance between the circuit
breaker contacts must be 3mm (0.1in).
The circuit breaker must be provided
with protection against the fault current
towards the ground (differential) and the
overcurrent (magnetothermal).
Electrical connections must be performed
with the power supply disconnected and
the circuit-breaker open.
A power disconnect device must be
included in the electrical installation, and
it must be very quickly recognizable and
operated if needed.
All disconnected wires must be electrically
isolated.
VIDEOTEC strongly recommend to test the
device configuration and performance
before putting it in the final installation
site.

8.1 Functional ground

If the unit is powered using an Ethernet
(PoE+) line, connection should take place
with a functional ground external cable,
towards the system ground.
Use cables with the characteristics outlined
below.
• Nominal section of the cables used:
2.5mm² (14AWG) min.
18
Installation of the functional ground cable as
illustrated in the figure.
Fig. 18

8.2 Quick connectors cabling

The product is equipped with quick connectors to
facilitate installation.
The back of the product has fixed connectors. You
must cable the connectors on the cable side (mobile
connectors).
Ethernet
CONN 1
Fig. 19
Rear view of the camera. Camera side connectors.
Once installation is complete, insert the mobile
connectors in the corresponding fixed connectors on
the back of the product.
If the mobile connectors are not used, fasten the cap
supplied on the back of the product.
CONN 2
MNVCNVX_2110_EN