GB
ENGLISH
7.1.2 - RS: Rotation speed display
Motor rotation speed in rpm.
7.1.3 - VP: Pressure display
Plant pressure measured in [bar] or [psi] depending on the measuring
system used.
7.1.4 - VF: Flow display
Displays the instantaneous flow in [litres/min] or [gal/min] depending on
the set measuring system.
7.1.5 - PO: Absorbed power display
Power absorbed by the electropump in [kW].
A flashing round symbol may appear under the symbol of the measured
power PO. This symbol indicates the pre-alarm for exceeding the allowed
maximum power
7.1.6 - C1: Phase current display
Motor phase current in [A].
A flashing round symbol may appear under the symbol of the phase cur-
rent C1. This symbol indicates the pre-alarm for exceeding the allowed
maximum current. If it flashes at regular intervals it means that the motor
overload protection is about to trip and it will very probably go into protec-
tion status
7.1.7 - Operating hours and number of starts
Indicates on three lines the hours that the device has been powered up,
the pump working hours and the number of starts of the motor.
7.1.8 - PI: Power histogram
A histogram of the power delivered is displayed on 5 vertical bars. The
histogram indicates how long the pump has been on at a given power
level. On the horizontal axis are the bars at the various power levels; on
the vertical axis, the time for which the pump has been on at the specific
power level (% of the time with respect to the total).
86
Figura 17: Power histogram display
7.1.9 - Multi-pump system
Displays the system status when in the presence of a multi-pump instal-
lation. If communication is not present, an icon depicting communication
absent or interrupted is displayed. If there are several devices connected
to one another, an icon is shown for each of them. The icon has the sym-
bol of a pump under which are characters indicating the pump status.
Depending on the operating status it will display as in Table 12.
System display
Status
Icon
Motor running
Symbol of pump turning
Motor stopped
Symbol of static pump
Device faulty
Symbol of static pump
Table 12: View of the multi-pump system
If the device is configured as reserve the top part of the icon depicting the
motor is coloured, the display remains similar to Table 9 with the excep-
tion that, if the motor is stopped, it shows F instead of SB.
7.1.10 - Output flow meter
The page shows two flow meters. The first shows the total output flow
delivered by the machine. The second shows a partial count and can be
Status information under the
icon
speed in three figures
SB