Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 112
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
10
20
30
40
50
60
70
80
Q (lt/1')
The same graph in Fig.6 shows in green other characteristic curves
corresponding to reduced rotation speeds of the same electropump. By
automatically modulating the rotation speed of the electropump, the in-
verter allows it to move its operation from one of the characteristic curves
to another, maintaining the constant set pressure value (SP). Practically,
the resulting curve of the system controlled by the inverter becomes the
one shown in Fig.7 (considering a default SP value = 3.0 bar).
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
10
20
30
40
50
60
70
80
90
100
Q (lt/1')
This means that, with SP = 3.0 bar, the system is able to ensure the
constant set pressure to utilities that require flow rates between 0 and
90 litres/minute. For higher flow rates the system works according to the
characteristic curve of the electropump at maximum rotation speed. For
flow rates lower than 90 litres/minute, as well as ensuring constant pres-
3000 rpm (impostati)
(set up)
2700 rpm (impostati)
(set up)
2400 rpm (impostati)
(set up)
2100 rpm (impostati)
(set up)
1800 rpm (impostati)
(set up)
1500 rpm (impostati)
(set up)
Figure 6
90
100
110
120
130
Figure 7
110
120
130
sure, the system reduces the absorbed power and therefore the energy
consumption.
The above performances are to be considered measured at
ambient temperature and water at about 20°C, during the first
10 minutes of motor operation, with water level at suction at a
depth of no more than 1 metre
As the suction depth increases, the performance of the electro-
pump decreases.

1.4 Technical characteristics

Voltage
Frequency
ELECTRIC POWER
SUPPLY
Maximum current
Maximum power
Overall dimensions
Empty weight (excluding
CONSTRUCTION
packaging)
CHARACTERISTICS
Protection class
Motor insulation class
Maximum head
HYDRAULIC
Maximum flow rate
PERFORMANCE
Priming
Maximum working pressure
Liquid temperature max
WORKING
Environment temperature
CONDITIONS
max
Storage environment
temperature
GB
ENGLISH
1 x 220/240 ~ VAC
50/60 Hz
11 A
1550 W
565x265x352 mm without
feet
24,8 kg
IP x4
F
65 m
120 l/min
<5min at 8m
8 bar
40 °C
50 °C
-10÷60 °C
67