PASSWORD
With the protection active, access to all the keys is blocked, except:
- the navigation and menu access keys ("ENTER" key and "arrow" keys): it is possible to navigate in the menu
pages and to view the various parameters, but any attempt to change them will require you to enter the password.
The only parameter that can be changed is the language.
- "RESET" key: in the event of an alarm, you can press this key to restart the pump.
When the correct password is entered, the keys are unlocked and the parameters can be changed; the "open
padlock" symbol appears on the homepage (paragraph 4.4).
When you have finished changing the parameters, the password can be reactivated from the homepage, by
selecting the "open padlock" icon (paragraph 4.4) and pressing "ENTER".
After eight hours of inactivity (without any keys being pressed), the password will be automatically reactivated
anyway.
If the password is lost:
•
Make a note of all the parameter values and reset the device the factory values (see par. 7.1). The reset
operation deletes all the device parameters, including the password, and thus re-enables the system.
5.2 Manual Speed Settings
MANUAL CONTROL
From the "Manual Control" menu, you can set the speed or flow rate parameters and the operating time associated
with the "SET 1-4" and "QUICK CLEAN" manual operating keys.
The manual speeds can also be changed directly with the "up" and "down" keys without entering the menu.
MANUAL SPEEDS
The parameters associated with the keys from "SET1" to "SET4" can be viewed and changed under this menu item.
ENGLISH
PARAMETERS
VALUES
Password
0000
XXXX
PARAMETERS
VALUES
Mode
FLOW/SPEED
S1-S4
E.swim 150
5 - 25 m
÷ 110 GPM)
E.swim 300
13 ÷ 32 m
(60 ÷ 140 GPM)
20% - 100%
T1-T4
10 min - 18 h /
24/24
64
DESCRIPTION
All the keys are unlocked and
usable and you can freely access
the various menus and modify all
the parameters.
The "key" symbol appears on the
homepage
Password set: the protection
system is activated. The "closed
padlock" symbol appears on the
homepage
DESCRIPTION
The first choice to make is whether
you want the setpoints "SET1-4" to
set the system regulation mode to
"Flow" or "Speed %".
/h (20
3
Setting the speed with flow control.
/h
3
Setting the speed with fixed curve
control (in percentage%)
Setting the duration time at the
relative speed.
The duration value indicates the
time that the speed remains
active, after which it ends; if you
want the speed to remain always
active without interruption, the
duration must be programmed as
24/24.