80
AVENTICS | DDL | R412009417–BDL–001–AD
Disassembly and Exchange
Fig. 6:
Exchanging the bus coupler, example
1
M5x35 hexagon socket head screws, 3 + 0.5 Nm
2
Bus coupler
8
Disassembly and Exchange
You can exchange the bus coupler, if needed.
The AVENTICS warranty only applies to the delivered
configuration and extensions taken into account in the
configuration. The warranty no longer applies after a
conversion that exceeds these extensions.
8.1
Exchanging the bus coupler
Applied voltage and high pressure!
Danger of injury from electric shocks and sudden pressure
drops.
Make sure the system is not under pressure or voltage
O
before you exchange the modules.
Observe the stipulated precautionary measures when
O
working with ESD-sensitive assemblies.
1
2
CAUTION
4
3
3
Seal
4
EP end plate VS HF03 LG or HF04