– Switch off the power supply before cleaning the
charging sockets.
– When using the charging cable, please ensure
that the maximum permitted force of 39 N (for
11 kW) and 48 N (for 22 kW) is not exceeded.
– Ensure only persons who have read these operat-
ing instructions have access to the charging sta-
tion.
2.3
Safety information for installation
– Installation and connection of the charging sta-
tion must only be carried out by an electrician.
– Only use the supplied installation material.
– The Webasto Live safety concept is based on a
power supply system that is earthed at all times.
The electrician must ensure this requirement dur-
ing installation.
– Do not install the charging station in an explosion
sensitive area (EX zone).
– Install the charging station in such a way that the
charging cable does not block any passageways.
– Do not install the charging station in areas sub-
ject to ammonia or air containing ammonia.
– Do not install the charging station in a location
where falling objects (e.g. extension reel or tyres)
can damage the charging station.
– The charging station is designed for use indoors,
e.g. garages as well as for use in protected out-
door areas, e.g. carports. Do not install the char-
ging station in the vicinity of water jets, e.g. car
wash installations, high pressure cleaners or
garden hoses.
– The charging station is suitable for use in areas
without access restrictions.
– The charging station shall not be exposed to dir-
ect rain to prevent damage due to freezing, hail
or similar.
– Protect the charging station from direct sunlight.
The charging current may be reduced at high
temperatures or charging may be disabled com-
pletely.
5110326B OI II Webasto Live Multilanguage
– The installation location of the charging station
should be selected such that vehicles cannot in-
advertently collide with it. Protective measures
must be implemented if the possibility of damage
cannot be ruled out.
– Do not place the charging station into operation
if it is damaged during installation. A replacement
will be required.
2.4
Safety information for electrical
connection
– Comply with the locally applicable requirements
pertaining to electrical installations, fire protec-
tion, safety regulations and escape routes at the
intended installation location.
– Each charging station must be protected with its
own line circuit breaker and residual current cir-
cuit breaker. See chapter 6.2 "Criteria for the
electrical connection".
– Make sure that the electrical connections are de-
energised before connecting the charging station
to the power supply.
– Make sure that the correct supply cable is used
for the power connection.
– Do not leave the charging station unattended
with the cover open.
– Register with the power supply company as re-
quired.
2.5
Safety information for initial start-up
– Initial start-up of the charging station must be
carried out only by an electrician.
– Prior to initial start-up, the electrician must check
that the charging station has been connected
correctly.
– Do not connect a vehicle during initial start-up of
the charging station.
– Before starting-up the charging station, check the
charging cable, charging coupling and the char-
ging station for visible damage. The charging sta-
tion must not be started up if it is damaged or if
the charging cable/charging coupling is damaged.
3
Unit description
See also Fig. 1
These operating and installation instructions describe the
Webasto Live charging station. The exact unit descrip-
tion is indicated on the type label of the charging sta-
tion.
3.1
Description of data interface connections
See also Fig. 2
Legend
USB-A
Modbus (RS 485) external
Micro SIM-slot
RJ 45 (LAN)
USB-B
With the cover open, the data interfaces can be found
on the left-hand side in the connection area. This area is
separated from the power supply area.
3.1.1 USB type A
This connection is used in host mode for a USB stick for
software or configuration updates. This connection sup-
ports the 5 V power supply up to maximum 100 mA.
3.1.2 Modbus
The data connection to a primary electricity meter can
be established for advanced power management. (see
online configuration instructions: https://webasto-
charging.com/documentation)
3.1.3 SIM card slot for modem
If it is necessary to change the GSM provider, then the
SIM card can be removed from the SIM card slot (pull
out, not automatically ejected by a spring) and an altern-
ative SIM card can be inserted. Prerequisites for using a
SIM card:
– Form factor 3FF (micro SIM)
– Service M2M without PIN, provider enabled
3.1.4 LAN
For connecting the charging station to the network in-
frastructure at the installation location. The charging sta-
tion can be configured and controlled using this connec-
EN
13