Figure 4: Loosen the screw connection on the left or right
5.4 Electrical connection
Important!
If the unit is fuse-protected with one or more large consumers, functional faults and damage can occur to the electronics!
• The unit must be connected to the voltage and frequency specified on the rating plate.
• To connect the unit, a 16A AC socket must be installed. This must be installed out of the animals' reach or be protected from them.
• The manufacturer accepts no responsibility and offers no guarantee for any damage caused by connections not set up by trained professionals.
• Local safety and earthing requirements must be observed. Ask your electrician!
6. Operation
Caution!
• The dip switch setting may only be made by a qualified electrician following consultation with Kerbl Service.
The unit must be disconnected from the voltage supply for this to be done.
• The dip switch setting is coordinated with this unit. If the default setting is changed, injuries can occur.
The responsibility for this setting lies with the customer.
6.1 Switching on
Once the power supply is connected, the unit is ready for operation after around 20 seconds. The unit indicates its readiness for operation by dis-
playing 3 lines in the display (see Fig. 6). Before that, the display shows the following:
• dIP – followed by the current dip switch setting, e.g. 16 A,
• APP – followed by the current software version, e.g. 1.18,
(for further information, see Point 6.3. Display and electronics).
Figure 6: Display message
6.2 Function
The motor is activated by raising the brushes since the internal contact switch is no longer actuated by the swing-out motor housing. The brushes
start to rotate for the set cycle time (factory setting 60 seconds). If the brush is in the rest position when the work cycle is finished, the motor swit-
ches off. At the next activation or if the brush is still raised after the cycle time has elapsed, the motor changes the direction of rotation in contrast
to the previous cycle and runs another cycle. By changing direction, the bristles are worn evenly and wear is reduced.
Figure 5: Swing the machine away from the base platform
Albert KERBL GmbH
Felizenzell 9
l
Fon +49 (0)8086 - 933-100
Fax +49 (0)8086 - 933-500
l
Mail info@kerbl.com
www.kerbl.com
l
STAT. REVISION NOTE
43
FINISHED SURFACE:
SCALE
ISO 5456-2 Projection
MATERIAL:
methode1
WEIGHT IN GRAMM
D-84428 Buchbach
l
General tolerances
(WITHOUT FINISHED SURFACE):
ISO 2768 - mK
1310432,150 g
DATE
NAME
TITLE:
DRAW
4.8.2021
sreinthaler
HappyCow UNO - Wall mounted
CHECK
ASM
NORM
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
ARTICLE NUMBER
PROJECT NUMBER
DWG NO.
KERBL:
KERBL:
27376
18680; 18690; 18700
NAME Urspr.
DATE
1:20
DET. SCALE
Albert KERBL GmbH
Felizenz
l
Fon +49 (0)8086 - 933-100
Fa
l
BASE SIZE/SEMI-
Mail info@kerbl.com
STAT. REVISION NOTE