13.4
General datas
Typ
Capacity (l/h) with control air pressure 6
bar and max. metering counterpressure
Metering back-pressure (bar)
Max. air control pressure (bar)
Max. Stroke frequency (strokes/min)
Min. activation time
Suction height (m) at 100% stroke setting
Suction / pressure connection ID / AD
Air connection AD
Voltage**
according to version
Output
**
Starting time
*
Suction heights with clean, moistened valves
**
Figures for pump fitted with solenoid valve
All figures based on water at 20°C and operation in accordance with the operating
NOTE
instructions
417101420_pneum_II.doc
**
PDP 00030
PDP 00060
3,6
6
240 msec. EIN / 240 msec. AUS
*
24 V AC / 50/60 Hz
48 V AC / 50/60 Hz
230V AC / 50/60Hz
- 47 -
PDP 00120
6,95
6
7
120
1,5
4/6 / 6/8 / 6/12
6
24 V DC
7 W
100 %
Rev. 4-07.10
12,6
6