NOTE: If the refrigerant is CONTAMINATED the machine will ask the connect an external
recovery unit in order to remove the contaminated refrigerant from machine. In order to
complete the cleaning of internal circuit the machine will run 10 minutes of vacuum.
The RECOVERY PROCEDURE will start, and the following screen will be displayed:
During the recovery phase, the machine displays the quantity of refrigerant recovered, in
grams.
Upon completion of recovery, the machine
displaying the used oil extracted from the A/C system during the recovery phase. The oil
discharge operation lasts 4 minutes
Unscrew and disconnect HP and LP coupling from A/C system end press ENTER.
INSTRUCTIONS MANUAL
Close and disconnect HP and LP couplings
from A/C system and press ENTER