automatic
optionally set permanently to 6 V, 12 V or 24 V
Charging parameters:
-
Boost (on/off), factory setting: on
Boost 'on': shorter charging time resulting in full charge being achieved sooner. The
full 35 A of power available from the device is applied if parallel consumers are detect-
ed (car radio, etc.).
Boost 'off' means that a conventional workshop charging process is followed (fixed
charging current of 20 A per 100 Ah of specified battery capacity). Parallel consumers
(car radio, etc.) are not detected in this case.
-
Expert (on/off)
Enter the following to activate Expert mode (Expert on):
Code number 1511
Expert mode (Expert on) allows a user application to be specified for WET, GEL and
AGM batteries when the device is in Charging mode. The following may be configured:
Charging end voltage
Conservation charge voltage
-
Buffering (Trickle) mode
Constant voltage may be adjusted
-
Refresh
Enter the following to alter the Refresh setting:
Code number 1511
Final charging voltage and duration may be adjusted
-
Power supply mode
Constant voltage may be adjusted
71