Interrupting Charging - Würth 0510 955 607 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

If the selection window for the battery voltage does not open, then the battery is in a state
of extreme deep-discharge (less than 2 V). In this case, it is advisable to use Refresh mode
to reactivate the deep-discharged battery. For more information, see the "Refresh mode"
section.
-
If Charging mode is still required despite the battery being in a state of extreme deep-dis-
charge
-
-
-
8
Interrupting
charging
60
Confirm the selection using the Stop/Start key
6
The relevant warning appears
Acknowledge the OK button in the warning using the Stop/Start key.
Use the up/down keys to select the correct battery voltage in the subsequent selection
window.
Confirm the selection using the Stop/Start key
CAUTION! Risk of sparks if the charger leads are disconnected too soon. Before
disconnecting the charger leads, press the Stop/Start key to finish charging.
To cancel charging:
7
-
Press the Stop/Start key
Disconnect the charger
-
Disconnect the black charger lead from the negative pole (-) on the battery
-
Disconnect the red charger lead from the positive pole (+) on the battery
NOTE! Danger of damage to connection sockets and plugs. Do not disconnect or
unplug charger leads while charging.
Press the Stop/Start key while charging
1
-
The process is interrupted
-
A set of four bars shows the state of
charge of the battery (e.g. the third bar
represents a state of charge of 80%).
-
All four bars are continuously display-
ed.
-
The state of charge is 100%.
-
The battery is ready to use.
-
The battery may remain connected to
the charger for any length of time.
-
Conservation charging counteracts
battery self-discharge.

Publicité

Table des Matières
loading