36
8.2
DRAFT CONTROL
EN
ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED EXCEPT
NOTE: Remove all source of gasoline or other fl ammable vapours and liquids in the vicinity of this or
other appliances prior to lighting.
Roll up some newspaper, light it and place it near the
appliance fl ue until the chimney begins to draw. When
a fi re is burning, open the door slowly to avoid drawing
smoke into the room.
A properly installed Napoleon appliance should not
smoke.
If yours does, check the following: Has the chimney had
time to get hot? Are the air intake hoods blocked
closed? Is the smoke passage blocked anywhere in the
appliance or chimney? Is the smoke fl ow impeded by too
long a horizontal pipe or too many bends? Is it a weak
draft perhaps caused by a leaky chimney, a cold outside chimney, too short a chimney, or a chimney too close
to trees or a higher roof?
W415-1501 / 05.15.15
DURING START-UP AND RE-FUELING.