24
5.5

MINIMUM MANTEL CLEARANCES

EN
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
An optional combustible mantle must be a minimum of 12" (305mm) above the top of the faceplate and not to
extend more than 2" (51mm) from the surface. See chart below for further information.
A = 8" (203mm)
B= 6" (152mm)
C= 4" (102mm)
D= 2" (51mm)
W415-1501 / 05.15.15
CLEARLY MAINTAINED.
HEAT RESISTANT TO PREVENT DISCOLOURATION.
A
B
E = 12" (305mm)
C
F= 14" (356mm)
D
G= 16" (406mm)
H= 18" (457mm)
E
F
G
H
TOP OF
FACEPLATE
(KEYSTONE)
43"
(1092mm)
WARNING
!
73.1