Check Spin; Results Recalculation - Hofmann EEWB746A Mode D'emploi

Table des Matières

Publicité

57
5-25
F3
5-25a
Operation
5.8.2

Check spin

it is good practice to perform a check spin after applying
the weights.
• Spin the wheel.
Having finished the Test Run, if the wheel is balanced
correctly, both the numerical indicators should indicate
0 and an OK should be displayed (Fig. 5-25).
Note
if there is no oK reading, dynamic unbalances below
the tolerance limit (suppression preset to 3.5 g) add to
a static unbalance above the tolerance limit.
To check how much imbalance is left:
• Select the FiNE key, F3 (Fig. 5-25a).
Note:
The operator should decide if applying the
stated weight is necessary.
5.8.3

Results recalculation

After spinning a wheel it is possible to enter new rim
data or select another weight mode. The results are
recalculated automatically, if possible.
Selecting another weight mode
• Between NoRMAL, ALu and STATiC: no additional
steps required.
To have a recalculation done:
• Select the required weight mode. Check and/or edit
rim or plane data when necessary.
• Rotate the wheel to the left plane WAP position and
apply the weight.
• Rotate the wheel to the right plane WAP position
and apply the weight.
• Perform a check spin.
Operator's Manual