Trouble shooting
E15
Recalibration correction is out of range.
During recalibration values above or below the
calibration value envisaged were found. This message
is only a warning.
use the clamping means supplied with the machine or
perform basic calibration (Service).
E16
During the first recalibration run the calibration weight
was attached by mistake.
unscrew the calibration weight and press START.
E17
Wheel slips on clamping means.
The clamping nut is not tightened properly, the main
shaft accelerates too quickly. The machine will stop.
Firmly tighten the clamping nut and in special cases
press the START key for longer.
E83
During a measuring run the values measured are
rendered useless due to outside interference pulses
(e.g.: strong vibrations). The run is interrupted.
Repeat the measuring run.
E88
The main shaft speed exceeds the safety limit.
E92
The gauge for measuring the distance and diameter
is faulty.
Call service team.
As long as the geodata measuring gauge is defective,
set the distance and rim dimensions using the menu
key and turning the wheel (Chapter 5.5).
93
EEWB746A
Operator's Manual