Operation
5.5
Selections by the User
The Type of Vehicle must always be set even if an
automatic function is used and it must be done before
extracting the rim position reading arms.
5.5.1
Selecting the Type of Vehicle
 on the RiM DATA ENTRY screen Fig. 5-11 press
the menu key F2 to select the Type of Vehicle.
 Select the TYPE oF VEHiCLE item according to
the rim on the machine.
When the selection has been made, the Type of Vehicle
in use identification icon will be displayed in the F2
taste Fig. 5-11.
Fig. 5-12 Assigned itemsTypes of Vehicle:
1 Standard vehicle wheel (car)- nominal dimensions in
inches.The unit of measure (inches) is displayed.
Normal and Alu 1 to Alu 5 weight positioning can be
selected. To select a standard wheel with nominal
dimensions in mm - TD or TRX wheel, you should
select the mm/inch option from Menu F6 in the
ENTERiNG RiM DATA screen (Fig. 5-11).
2 Light industry vehicle wheel (Van) - nominal
dimensions in inches. Executable steps are
expressed in the "Product Requisite" table at the
end of the manual.
The threshold value for suppression of minor
unbalances is automatically doubled when this type
is chosen and the resolution of the amount reading
set to 10 g and 5 g respectively.
3 Motorcycle wheel - nominal dimensions in inches,
with imbalances resolved and suppressed in the
same way as car wheels. Consult executable steps
in the "Product Requisite" table.
5.5.2
Manual entering of the rim Width
Rim width is entered via the menu keys, the rim
diameter can be determined manually .
if rim width is not given on the rim, it can be measured
on standard rims using the optional rim width callipers
(Fig. 5-13 – Ref. no. EAA0247G21A).
 Access the ENTERiNG RiM DATA (Fig. 5-13a)
screen and select the Menu key F4
 Read the nominal diameter on the rim or tyre and
note it down.
 Press the menu key - or + (1, 2, Fig. 4-15) until the
required value is reached.
 Press the menu key F4 or OK to set the value.