Maintenance

6.2 Readjustment by the operator

if several measuring runs are necessary to balance
a wheel because balance weight size and position
have to be adjusted repeatedly, this is often due to
insufficient measurement accuracy.
if this is the case the operator can electronically calibrate
the rotating masses on the machine; which is called user
Calibration.
A calibration run takes longer than a regular measuring
run.
Following user Calibration any residual compensation will
be cancelled.
important:
User Calibration should only be performed with
nothing on the shaft; and with no external tools
whatsoever on the wheel holder.
Readjustment
 Make sure that no clamping tool (and no wheel or
other device) is mounted on the machine shaft.
 Press the F2 key in the MAiN MENu three times
(Fig. 6-1) and select the CALiBRATioN key (1, Fig.
6-2).
The CALiBRATioN 1 screen (Figure 6-5) will open.
 Close the wheel guard, press the START key and
launch the first calibration run (if the run takes a
long time it means residual imbalances have been
detected).
The CALiBRATioN screen 2 will open.
 Screw the Calibration weight onto the threaded
hole in the wheel support flange (Figure 6-6).
 Press the START key and launch a second
calibration run (to detect correction values).
After the second run the electronic control unit
processes the values taken during the calibration runs
and writes them in the permanent memory. When
this has finished an audible 3-tone signal is heard to
indicate that user Calibration has terminated.
 Unscrew the Calibration weight from the flange and
put it back in its designated place in the Weight
Holder Tray.
 Press the ESC key to return to the iNTRoDuCTioN.