General Safety; Inspect Your Shipment - Franklin Electric BT4 Serie Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WA R N I N G
voltage. See ELECTRICAL
INSTALLATION section of this
manual and motor nameplate.
connecting to power supply.
Hazardous voltage.
Can shock, burn, or
Code (NEC) or Canadian
cause death.
Electrical Code (CEC) and local
Ground pump before
codes for all wiring.
connecting to power
supply. Disconnect
power before working
instructions provided in this
on pump, motor
or tank.
manual.
C A U T I O N
DO NOT touch an operating motor. The
surface of the motor may be HOT. Allow the motor to
cool for thirty (30) minutes before handling.

GENERAL SAFETY

Do not allow pump or any system component to freeze;
doing so will void the warranty. This pump has been
evaluated for pumping water only. Pumping liquids other
than water may void warranty.
Maximum operating pressure is 500 psi.
Maximum suction (incoming) pressure is 75 psi.
Maximum water temperature is 120 °F.
Periodically inspect pump and system components.
INTRODUCTION
The BT4 horizontal booster pump is a low to medium
capacity, high pressure, multi-stage unit. Although the
BT4 horizontal booster pump will typically be used as
a part of a larger water system, it is also capable of
acting as a water system's primary pump. (The BT4
should not be used to lift water more than 10 ft) The
BT4 can function as a multi-purpose high pressure
pump, boosting water pressure from either city mains
or private water systems. It is also ideal for applications
that require more pressure than flow, such as industrial
cleaning equipment, car and truck washing, pressure
washing of commercial and residential buildings, fire
suppression systems, general water use in multi-family
structures, spray cooling in poultry and livestock houses,
and lawn and crop irrigation. Siphon injectors may also
be added to the system to inject chemicals externally to
the pump's discharge, further expanding the scope of
applications for the BT4.
FEATURES
SUCTION BRACKET / PUMP BASE / CARRYING
HANDLE - All integrated into one piece for convenience,
durability, strength, and expanded functionality. The
bracket can be made of either cast iron or stainless steel
DISCHARGE HOUSING - Stainless steel with a
1" FNPT opening
PUMP SHELL - Stainless steel
2
Wire motor for correct
Ground motor before
Meet National Electrical
Follow all pump wiring
IMPELLERS AND DIFFUSERS - Glass reinforced
engineered thermoplastic, which is highly resistant to
abrasive and corrosive conditions. Each hydraulic stage
is built with Franklin Electric's Patented (US Patent No.
7,290,984) TRI-SEAL™ Floating Stage System to ensure
years of dependable operation
SHAFT - 7/16" stainless steel hexagonal rod
COUPLING - Stainless steel or brass machined to the
proper fit to ensure a secure motor connection with no
power loss between the motor and the pump
MECHANICAL SEAL - Carbon/ceramic
ELECTRIC MOTOR - On complete pump/motor
assemblies: Square flange, thermally protected, dual
voltage, 115-230 V single-phase or 208-230/460 V 3-phase,
and hp ranging between 1/2 and 3, ensuring the proper
motor is available to meet a wide range of applications.
On Pump End Only: Requires separate purchase of a
56C Frame, keyed shaft motor design to meet or exceed
rated horsepower of pump.

INSPECT YOUR SHIPMENT

All horizontal booster pumps are carefully tested,
inspected, and packaged to ensure their arrival in
working condition. When the pump is received, examine
it closely to make sure parts have not been damaged
or broken as a result of shipping. If damage is evident,
report this immediately to your shipping carrier and
dealer. The shipping carrier assumes full responsibility
for the shipment's safe arrival. Any claim for damage to
the shipment, either visible or concealed, must be made
through the shipping carrier first.
INSTALLATION
(Appendix 3 – Installation Records)
LOCATION OF THE PUMP
Decide on a location for the pump installation that is
suitable based on the enclosure rating of the pump's
electric motor.
NOTICE: 1/3 – 2 hp BT4 booster pump/motor
assemblies are CSA Certified for use for in USA and
Canada and will be marked "ACCEPTABLE FOR
OUTDOOR OR INDOOR USE." 3 hp booster pump/
motor assemblies are CSA certified for use in the USA
and Canada and will be marked "ACCEPTABLE FOR
INDOOR USE ONLY".
Adhere to the guidelines of national, state, and local
plumbing codes when installing this product. Check with
the appropriate agencies or water system professional
for additional information.
INDOOR PUMP INSTALLATION OPTION
Choose a clean, well-ventilated, weatherproof location
that provides protection from freezing, flooding, and
excessive heat. In addition, it should provide access for
servicing and allow convenient draining of the pump,
tank, and service pipes. A prepared foundation is not
essential, provided the surface is hard and level. It can
be mounted either horizontally (Figure 1 and Figure 2) or
vertically (Figure 3) depending on the space available.

Publicité