SAFETY WARNINGS

BEFORE OPERATING OR
INSTALLING THIS PUMP, READ
THIS MANUAL AND FOLLOW
ALL SAFETY RULES AND
OPERATING INSTRUCTIONS.
SAFETY
CAREFULLY READ THESE SAFETY MESSAGES
IN THIS MANUAL AND ON PUMP.
CAUTION
DO NOT OPERATE THIS PUMP DRY!
Review instructions before operating.
WARNING - ELECTRICAL PRECAUTIONS
All wiring, electrical connections, and system grounding
must comply with the National Electrical Code (NEC)
and with any local codes and ordinances. Employ a
licensed electrician. For non-thermally protected motors
use with approved motor control that matches motor
input in full load amperes with overload element(s)
selected or adjusted in accordance with control
instructions.
Adhere to the guidelines of national, state, and local
plumbing codes when installing this product. Check with
the appropriate agencies or water system professional
for additional information.
These pumps are suitable for installations where the vertical distance from the pump to the water level does not exceed 25 ft (7.5m),
including drawdown. In all installations friction losses in the piping must be taken into consideration.
HP
1/2
3/4
1
1-1/2
2
3
5
a)
PUMP LOCATION: The pump should be installed in a
clean, dry and ventilated location. Provisions should
be accommodated for adequate drainage, room for
servicing, and protection from freezing temperatures.
The unit should be bolted down evenly on a good
foundation, preferably concrete, to prevent the
development of unnecessary stresses. Locating the
pump as close as possible to the source of water supply
reduces the friction losses in the suction pipe and
provides maximum capacities.
20
30
40
50
46
40
37
30
56
52
47
42
61
57
54
49
69
67
63
59
90
89
87
83
140
140
132
124
152
152
152
152
WARNING
This equipment must not be used by children or persons
with reduced physical, sensory or mental abilities, or
lacking in experience and expertise, unless supervised
or instructed. Children may not use the equipment, nor
may they play with the unit or in the immediate vicinity.
WARNING - RISK OF ELECTRICAL SHOCK
Have an electrician provide electrical power
to motor.
All wiring and electrical connections should comply
with the National Electrical Code (NEC) and with
local codes and ordinances.
A ground fault interrupter (GFI) protected circuit is
recommended for use with any electrical device
operating near water.
WARNING
If power cord suffers damages, consider this product
does not allow partial replacement and therefore should
be fully replaced.
APPLICATION
PERFORMANCE
Total Head in Feet
60
70
80
Capacities in U.S. GPM
22
12
-
36
29
19
44
39
32
54
49
43
79
72
63
116
107
98
152
150
141
INSTALLATION
b)
SUCTION LINE: Before installing the suction line, check
the pump rotation as outlined below. It is recommended
that only new, clean pipe or suction hose be used and the
size be the same as that of the pump suction tapping. If
the pump is installed any appreciable distance away from
the source of water supply, the suction pipe should be
increased by one size. The suction pipe should never allow
a downward water flow in its connections from water supply
to the pump (see Fig. 1). A foot valve must be connected
to the bottom of the suction line and should be clear of any
possible obstructions.