Automatic repositioning
If the programmer blocks due to an encoder count error
programmer reset
, the warning lights and indicator light will flash simul-
taneously for 2 seconds and will then switch off for 0 seconds.
After the programmer has been in this condition for 3 minutes it will (after
pre-flashing for 0 seconds) automatically move the gate, slowly, to the
completely closed position (2 times as in the programming procedure) in
order to recover the correct position.
DISPLAY MODE
using the PROG button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
If the gate is not closed the display will not switch off
and will light up the segments indicating the
command status again.
Memorising the DIP-SWITCH settings
The segments regarding the command status
(LED "ON" = command active) and safety status
(LED "ON" = safety device at rest) light up.
Activating Tb-FTCI-CSP resets the display time
(additional 10 seconds).
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the "test" mode (only activated when the motor has
stopped) it is possible to check the status of the
command and safety devices and carry out eventual
maintenance. The warning lights will activate once,
each
time
a
"TA-TC-TAL-TD-Tb-FTCI-CSP"
command is received.
In
this
mode
you
can
communication by using the external program, which
is to be connected to the CSER connection via cable
(fig. 10).
While communication is active dashes will appear on
the display; after 5 seconds of inactivity you will be
moved back to the "test" mode.
To return to the normal operating mode press the
"test" command again and wait for 10 seconds.
Limited opening setting from 1 to 9 metres (in the
example it has been set to 3 metres).
Each time "PROG" is pressed
the limited opening distance,
measured
in
metres,
increase (from 1 to 9).
10 seconds after the last
modification you will be
automatically moved out of
the mode and the selected
values will be saved (eg. 4)
or after a
PRESS PROG
PRESS PROG
PRESS PROG
activate
serial
line
PRESS PROG
PRESS PROG
0 sec
PRESS
will
PROG
0 sec
At this point the programmer will function normally.
To carry out automatic repositioning without waiting for 3 minutes you may
send a (TA, TC, TAL or TD) command to the programmer.
No commands will be accepted during repositioning but the security devices
will cut in and block all movement if they go into alarm.
• To interrupt the repositioning manoeuvre and delay it for another 3 minutes,
press the "PROG" button.
- display the number of manouvres;
- access the "test" mode;
- set the limited opening distance.
0 sec
Nr. of decimal points lit
0 sec
When the
("TA-TC-TD-TAL-Tb-FTCI-FTCS") inputs
are activated the warning lights will light up.
Connect the
programming device
(CSER) and activate it.
5 sec
7
Add to the total
on the display
+ .000.000
PRESS PROG
0 sec