Repositioning
Attention! During the repositioning manoeuvre the current sensor value "SnS"
could be different leading to a momentary increase in the door impact force. At the
end of the manoeuvre, however, it will reset automatically to the chosen value.
If the programmer blocks due to an encoder count error
mer reset
, when one of the motors has been released
problem with one of the motors
flash simultaneously for 2 seconds and will then switch off for 10 seconds.
DISPLAY MODE
Using the PROG button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
- display the number of manoeuvres;
The status of the security devices TB, FTCI,
FTCS and CSP are always shown on the display.
Memorising the DIP-SWITCH settings and
displaying the firmware version (e.g. "12")
The segments regarding the command
status (LED "ON" = command active) and
safety status (LED "ON" = safety device
at rest) light up.
The number of manoeuvres appears on the
display. This number always remains visible
until you change the setting. Once 999999
has been exceeded the lighting up of the
decimal point on the display equals 1 million
+ the six figure number.
PRESS
PROG
APL
= Setting the limited opening space:
1 = 1/3 of the distance of gate 1 : 2 = half the distance of gate 1
3 = 2/3 of the distance of gate 1 : 4 = the entire distance of gate 1
PRESS
PROG
SNS = Setting the current sensor.
1 = motor consumption + 2 amps
2 = motor consumption + 3 amps
3 = motor consumption + 3,5 amps
PRESS
PROG
Selecting the type of motor
BL1924 = Articulated operator (without PRG)
BL3924 = Articulated operator (self-locking)
BL39rb = Articulated operator (reversible)
inSidE
HL2524 = Underground operator
BL224E = Straight arm operator
PRESS
PROG
Reclosing after encountering an obstacle
0 = unlimited number of closing attempts
1-3 = maximum number of closing attempts
, after a program-
or there is a
the warning lights and indicator light will
PRESS PROG
PRESS PROG
PRESS PROG
= inside operator
If in this stage you send a (TA, TC, TAL or TD) command to the programmer.
The programmer will move the gates slowly to the completely closed position
(2 times as in the programming procedure) in order to recover the correct posi-
tion. At this point the programmer will function normally. If a "TA" command
is given the positioning recovery is carried out in the opening direction.
No commands will be accepted during repositioning but the security devices
will cut in and block all movement if they go into alarm.
test
- set the limited opening distance;
- set the current sensor level;
- selecting the type of motor;
- reclosing after encountering an obstacle.
In the test
10 sec
has stopped) it is possible to check the status
of the command and safety devices.
The warning lights will activate once, each
time a "TA-TC-TAL-TD-TB-FTCI-FTCS-CSP"
command is received. To return to the normal
mode press the button again "test" will
appear, then wait for 10 seconds.
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 1 to 4).
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 1 to 3).
10 sec
PRESS PROG
Each time the button is pressed the
setting changes.
10 sec
PRESS PROG
Each time the button is pressed the
number increases (from 0 to 3).
10 sec
19
PROG" or "TB" button.
10 sec
PRESS PROG
TA-TC-TD-TAL-TB-
FTCI-FTCS-CSP
e activated
the warning lights will light up.
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. 4)
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. 3)
10 s after the last
modification you will
automatically exit the mode
and the selected value will
be saved (eg. inSidE)
10 s after the last
modification you will
automatically exit the mode
and the selected values will
be saved (eg. 2)