IMPORTANT REMARKS
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS
CAREFULLY bEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION
TO ALL THE PARAGRAPHS MARKED WITH THE SYMbOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.
• These instructions are aimed at professionally qualified "INSTALLERS OF
ELECTRICAL EQUIPMENT" and must respect the local standards and
regulations in force. All materials used must be approved and must suit the
environment in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified
technicians.
• This appliance must be used exclusively for the purpose for which it has been
made. "i.e. for the automation of gates and doors". The unit 00/SL524
can drive sliding gates with weights of up to 500kg.
• This product and all its relative components has been designed and manu-
factured by Cardin Elettronica who have verified that the product conforms
in every aspect to the safety standards in force.
Any non authorised modifications are to be considered improper and therefore
dangerous. The manufacturer accepts no liability for situations arising from the
use of an electrical installation which does not conform to the local standards
and regulations in force and in particular when the earthing circuit is not efficient.
• After having installed the device, and before powering up the programmer,
release the gate (manual release mechanism) and move it manually, checking
that it moves smoothly and has no unusual points of resistance.
Caution! The installation of both anti-derailment buffers
is absolutely obligatory.
The programmer can activate the motor automatically.
This is indicated by the warning lights pre-flashing for 10 seconds,
and by the symbol
repositioning" on page 17).
• The programmer is fitted with an electrical input monitoring system, which
is used to block the motor in emergency conditions; however this system is
not active during the following stages:
- during the first 5 sec. of an opening stage starting from completely closed
- during the first 2 seconds of all other movement stages
- when the battery undercharged
Do not therefore attempt to physically block the door during these stages,
All rights reserved. unauthorised copying or use of the information contained in this document is punishable by law
otherwise you may risk blowing the motor circuit protection fuse "F".
Note: If you need to check the status of the fuse "F2", disconnect the power
supply to the programmer; reconnect it only after having re-inserted the fuse.
Warning! The presence of the electrical input monitoring system
does not exclude the need to install photoelectric cells or other
safety devices which are foreseen by the local standards and
regulations in force.
Warning! The geared motor unit has been assembled in the factory
to be fitted to the left side of the gate. Read the paragraph on page
14 "instructions for positioning the unit".
Warning! For the correct operation of the programmer the incor-
porated batteries must be in good condition: the programmer will
lose the position of the gate in case of blackouts when the bat-
teries are flat, the alarm will sound and automatic repositioning
will take place .
Check the good working order of the batteries every six months
(see page 19 "battery check").
OVERALL DIMENSIONS
IMPORTANT REMARKS
Q
appearing on the display ("automatic
5
330
. NOT READING THESE IMPORTANT
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main
road to eliminate possible traffic disruptions and that the size of the gate, the
distance from the road and the work cycle speed can in no way interfere,
causing possible traffic hazards.
2) The motor must be installed on the inside of the property and not on the public
side of the gate. The gates must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are
passing. Pedestrians should use a separate entrance.
4) Make sure that the end-user is aware that children and/or pets must not be
allowed to play within the area of a gate installation. If possible include this
in the warning signs (see point 6)
5) The gate must be in full view when it is operating therefore controls must be
situated in a position where the operator can see the gate at all times.
6) At least two warning signs (similar to the example
on the right) should be placed, where they can be
easily seen by the public, in the area of the system
of automatic operation. One inside the property and
one on the public side of the installation. These signs
must be indelible and not hidden by any objects
(such as tree branches, decorative fencing etc.).
7) A correct earth connection is fundamental in order to
guarantee the electrical safety of the machine
8) If you have any questions about the safety of the gate
operating system, do not install the operator. Contact your dealer for assist-
ance.
TECHNICAL DESCRIPTION
- Mains power supply 230 Vac.
- Motor powered with a maximum voltage of 37 Vdc.
- upper and lower cover in highly resistant shock-proof plastic.
- The reduction unit stator is made of die cast aluminium and contains a never
ending screw and double reduction lubricated with permanently fluid grease.
- Irreversible reduction system with a key operated manual release mecha-
nism.
- The incorporated electronic programmer contains the power stage, the logic
control, battery charger and the radio receiver decoding module. The power
supply is routed to the electronics card via a separate transformer which is
housed in the same container and is connected to the card by faston clips.
- The system is fitted with electronic deceleration control which reduces the
stress caused by the gate inertia when it stops.
Accessories
06/SLOPC - m Glass fibre toothed rack 20 mm x 20 mm
(upper fastening ovals)
06/SLOPC - m Glass fibre toothed rack 20 mm x 20 mm
(lower fastening ovals)
950/xLbS03 - Rubber buffer H60 + aluminium support
950/xLbS - Pressure switch for safety edges. When connected to a closed
rubber buffer it translates a pneumatic signal into an electrical command which
can be interpreted by the electronic programmer as an inversion command.
Complete with a m long 6x diameter flexible tube and a connection joint to
interface with the closed rubber tube.
240
65
25
2
IMPORTANT REMARKS
65
65
WARNING
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
bE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
3