IMPORTANT WARNINGS
The control panels have different features to store the products safely in the refrigerator, and also it has some
special features to identify the problems easily.
IMPORTANT NOTICE: Closing of your product only from the control panel allows you to switch to stand-by mode.
To disconnect power from the control panel, close the plug from the socket.
PRODUCT OPENING: Press and hold the POWER button press for 4 seconds.
TO SET THE TEMPERATURE: Press the set button continuously. The "C" icon will start blinking, and you will see
the SET temperature of the product. Use the up and down buttons to set the temperature that you desire, press
the SET button. The temperature SET Value will start blinking and then it will stop. Now you can use the product
in the new setting temperature. The product will work with + 3 C° difference.
H.A.C.C.P FEATURE: If there is already an alarm in the device memory, on the screen will appear.
ALARMS EXPLANATION
LA: Low temperature alarm;
Reason: Malfunction of the temperature reading sensors
Solution: On the control panel you will see P1, P2 or P3 identifying which sensor is not working, please contact
the technical service
Reason: Digital thermostat malfunction.
Solution: Please contact technical service
HA: High temperature alarm;
Reason: While loading to close the air blowing canals of the product.
Solution: Make sure you load the products as it is shown in the user manual.
Reason: The evaporator fan is not working.
Solution: Changing the factory settings of the parameters or malfunctioning fan, get in touch with the technical
service.
Reason: The door is left open.
Solution: Make sure that the door is closed and sealed completely. When the cabin is empty the setting
temperature must be reached in 60 minutes.
Reason: To put high temperature materials inside before the product reached the setting temperature.
Solution: When there is a problem with the inside the cabinet temperature, to prevent to spoil the food inside
the inside fans will stop working after a certain temperature level. If you put hot materials before the inside of
the cabinet have reached the desired temperature, the cabinet temperature will not drop. Make sure that the
product has reached the desired temperature before loading the cabinet.
dA: Door switch alarm;
If the door of the unit is left open too long to effect the inside temperatures of the products, 'dA' will appear on
the screen to tell you that the door must be closed. When you close the doors the screen will be normal. (This
feature is not present in all products)
'P1', 'P2' ,'P3' DIGITAL THERMOSTAT PROPE ALARMS
Reason: Malfunction of the temperature reading sensors.
Solution: On the control panel you will see P1, P2 or P3 identifying which sensor is not working, please contact
the technical service
IMPORTANT WARNING
THE DIGITAL PARAMETER SETTING HAS BEEN PROGRAMMED FOR THE UNIT TO PERFORM THE BEST WAY. DO
NOT CHANGE ANY OF THE PARAMETER SETTING OTHER THEN SIMPLY SETTING THE TEMPERATURE. TO
CHANGE THE PARAMETERS SETTINGS CAN CAUSE SERIOUS PERFORMANCE DECRESAES AND CREATE SERIOUS
PROBLEMS IN THE UNIT.
26