13.1 PREPARATION BEFORE ACTIVATION
Make sure the cables and electric power that connecting to product provide the necessary electrical
power.
Make sure Counter type and Vertical type refrigerator is placed away from heat sources. Such as
furnaces, radiators, direct sunlight.
Leave space at least 75 mm (3 inch) at the back of the refrigerator. This is important for condensation.
Cooling unit should be away from strong air flow obstructions, should be a place where comfortable
and breathable.
With the upper body of refrigerator and attic must be min.50 cm (9 inch) space.
Should be maximum ambient temperature of +43 ° C (+109 ° F) for products in order to work correctly. It can
be highest ambient temperature +32 ° C (+95 ° F) where using static cooling system products.
Failure to comply with the above conditions, operating performance of the product will be serious decline,
premature wear of the compressor and also consumes more energy than usual.
13.2 CONNECTION
Please follow the instructions listed below.
13.3 ELECTRICAL
Making horizontal and vertical electrical connections is under user's responsibility. Check that the electrical
connections according to the rules of electrical connection the country.
Check even voltage be sure that the same written on the label.
Check electrical outlet that according to electrical power rules.
Check whether Exposed cable.
Check the grounding.
USE OF DEVICE IS DANGEROUS AND ILLEGAL WITHOUT GROUNDING.
If you are connected multiple products to the same source, there should be a separate electrical outlet each
other.
13.4 DRAINAGE CONNECTION
If you do not have evaporator in your product, it must be connected for the water drainage hose for removal
of water out.