A.4 EXIT FROM PIT
· to operate on the mechanical stop car device placed on the guide
-
pull down the black handle
-
the device in now not on working
-
put the device not on working also deactivate the safety switch that
power off the maintenance push-button panel.
If the lower landing door is closed
· Open the door
-
To pull down the handle of the unlocking door remote control
-
Manually move the door panel in the opening direction
-
Move the handle of the unlocking door remote control to the initial
position
· Exit from pit using the proper anti-slip ladder placed under the sill of the
landing door
· From floor, staying out of the well or the pit, move the stop push-button to
the standard working position (remove from safety stop)
· Close the door
· To operate on the remote push button panel:
-
Rotate and keep the key (KY) to the ON position
-
At the same time push the descent button (DN)
-
Rotate the key (KY) to the OFF position
· Close the remote control box door
· Remove all the out of service sign from all landing doors.
A.5 PERIODICAL MAINTENANCE AND CHECKS TABLE
O
I. Group : MRL Devices
Car stop electrical device
I.a
Car stop mechanical device
I.b
Remote landing door unlock device
I.c
Remote control station
I.d
Remote hand pump
I.e
A.6 MAINTENANCE SCHEDULES
II. Group : MRL Devices
What to do:
II.a Car stop electrical device
-
Check that the switches on guide rails, correctly work, are well tights and in the correct position
II.b Car stop mechanical device
-
Verify that the mechanical device correctly work
-
Verify that the rope slides easily into the guide and if necessary lubricate it.
-
Check that the safety switches of the device correctly work
II.c Remote landing door unlock device
-
Verify that the unlock device correctly works.
-
Verify that the rope slides easily into the guide and if necessary lubricate it.
-
Make sure that rope fixings are well tights and clean.
II.d Remote control station
-
Check, for safety, that all the devices of the remote control station correctly work.
II.e Remote hand pump
-
Verify that the hand pump correctly works and that losses of oil are not taken place
· Change or restore all components that don't work properly.
Maintenance Manual
Procedures for MRL lift
PERATION CHECKS
Pag. 4 di 4
Doc. n° 10991032
Rev.
1.0.11
OFF
R
ECOMMENDED MAXIMAL
I
6
NSTALLATION
MONTH
þ
þ
þ
þ
þ
þ
þ
þ
þ
þ
A
EN
- 07.06.2006
F
REQUENCY
5
YEARS
6