DISPOSAL
Recycle a tool damaged beyond repair at the appropriate facility.
Contact your local municipality for a list of disposal facilities or
by-laws for electronic devices, batteries, oil or other toxic liquids.
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does
not function properly or parts are missing. If unable to do so,
have a qualified technician service the tool.
PROBLEM(S)
No response
after turning
on power
supply.
Fan doesn't
work after
turning on
the power
supply.
No Air.
Can't cut
material or
no current
output.
28
30A PRO CUT 30 PLASMA CUTTER
POSSIBLE CAUSE(S)
Power supply has
wrong phase.
Power supply switch is
broken.
Fuse is blown.
No input voltage.
Fan is damaged.
Fan's down-lead is
broken.
Fan blade is blocked.
Transformer is ruined.
Air valve is damaged.
Air circuit is blocked.
Down-lead is broken.
Discharge gap is too
big.
Workpiece is too thick.
Electrical cir`cuit
incomplete
Improper grounding.
For technical questions call 1-800-665-8685
SUGGESTED SOLUTION(S)
Plug into single phase
power supply.
Replace power switch.
Replace fuse.
Check outlet and power
supply cable for power.
Have electrician repair
either if not working.
Replace.
Examine and repair.
Remove the blockage.
Replace transformer.
Replace air valve.
Clean the blockage.
Examine and repair.
Adjust to suitable gap.
See Specifications.
Check that the ground cable
is properly connected.
Check that the ground
clamp contact point is
clean.