3.4
Start up
Warning
•
Never pour biodiesel or vegetable
oil onto a hot burner dish. The
burner dish must be cool and clean!
•
Do not start the heater if the fan still
runs. The heater is cooling down.
•
Do not start the heater if excess oil
has accumulated in or near the
heater.
Caution
Do not switch on the convector heater if
there is no fuel, or if the connected fuel
tank is empty.
Caution
Only the following oil types may be used
in the stationary biodiesel or vegetable
oil fired heaters:
•
Biodiesel
•
Vegetable oil
1.
Switch the rocker switch to "2", see fig. 6 (D).
When the burner dish has reached the right
temperature, the fuel pump starts running
and the control light is on.
2.
During the first 20 - 30 minutes the fuel pump
should have a low capacity.
Position the rocker switch to "low", see fig. 5
(A).
3.
Set the pump regulator to high capacity if
maximum capacity is desired.
Switch the rocker switch to "high", see fig. 5
(B).
5
MAINTENANCE
5.1
Maintenance table
Use the table in this booklet to record performed
maintenance after each winter season.
Warning
For all service and adjustments contact
qualified, competent and authorized
persons.
Description
Clean the burner dish.
Bio Energy - US
4
4.1
4.2
Switch off heating:
1.
Switch the rocker switch to "0".
The fuel pump stops running.
The control light turns off.
/i
Period
Every
12
hours
X
40.020.952 - rev. 04 - 2011
USE
During operation
Caution
•
Do not operate the heater in hot
weather to burn oil.
•
Do not burn oils other than
generated on the premiss of the
owner, unless written authorization
is obtained from the regulatory
authority.
Hot
Do not touch the flue stack or blower
outlet! The flue stack and blower outlet
get hot during operation!
Switching off
Caution
After switching off the heater it will run
for several minutes, until the fuel on the
burner dish is used up. In the meantime
the hot air fan and the distributor fan
keep running. These fans cool the
heater until it has sufficiently cooled
down (after 10 to 30 minutes).
Both fans will stop around the same
time.
Warning
Always clean the combustion chamber
before starting the heater.
Hot
Do not touch the flue and air outlet!
Wait until the flue and the air outlet have
cooled down sufficiently before carrying
out any maintenance.
Week-
Month
Every
Annu-
ly
ly
six
ally
month
s
English
Every
two
years
45