THERMOBILE Bio Energy - US Manuel De L'utilisateur page 49

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fault
The flame is extinguished
immediately after ignition; the
control light is off.
The air combustion fan keeps
running, while the hot air fan
has stopped and the heater
has cooled down.
There is soot formation in the
combustion chamber and in
the flue.
There is soot formation in the
combustion chamber and in
the flue.
Bio Energy - US
Cause
3
The motor and pump are
not functioning.
4
The pump thermostat has
not reached the right
temperature yet.
5
The maximum thermostat
is defective.
6
The overflow protection is
full of biodiesel or
vegetable oil.
7
There is water or sediment
in the fuel tank.
8
The fuel supply pipe is
blocked: The fuel flows
back into the fuel tank
through the return pipe.
9
There is no proper flue
draught.
10 The combustion
thermostat is defective.
11 The combustion air fan is
not functioning.
12 There is insufficient supply
of combustion air
13 The flue draught is too
high or irregular.
40.020.952 - rev. 04 - 2011
Solution
Check the pump thermostat and
replace if necessary.
Check the overflow protection
switch by moving the overflow
basin a few times from left to
right.
Check whether the pump axis
can be turned manually. Clean
the pump if this is not possible.
Check the pump motor.
Let the heater cool down.
Restart the heater.
Replace the pump thermostat.
Reset the thermostat.
Replace the thermostat.
Clean the overflow basin, burner
dish and the bottom of the
vaporiser.
Clean the fuel tank and the fuel
filter, see fig. 3.
Clean the fuel supply pipe or
replace if necessary.
Check whether the flue is fitted
according to the description, see
"flue".
Check the flue for leakage.
Clean the flue if necessary.
See faults: 3 and 4.
Replace the combustion
thermostat.
Check the motor and replace if
necessary.
Clean the holes in the vaporiser. User
Check the functioning of the
combustion air fan.
Position a flue stack valve, see
"flue".
Adjust the flue to the right
pressure, see § 5.3.
See faults: 9, 12, and 13.
English
Action
Dealer
User
User
Dealer
User
Dealer
User
User
User
User
User
User
User
User
User
Dealer
User
Dealer
49