Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
3.4
Starting up
Warning
Never pour diesel oil onto a hot
burner dish. The burner dish
must be cool and clean!
Do not start the heater if the fan
still runs. The heater is cooling
down.
Do not start the heater if excess
oil has accumulated in or near
the heater.
Caution
Do not switch on the convector
heater if there is no fuel, or if the
connected fuel tank is empty.
Caution
Only the following oil types may be
used in the stationary used oil fired
heaters:
Automatic transmission oil
Crankcase oil
Diesel oil
Hydraulic oil
Domestic fuel oil
1. Switch the rocker switch to "2", see fig. 6
(D).
When the burner dish has reached the
right temperature, the fuel pump starts
running and the control light is on.
2. During the first 20 - 30 minutes the fuel
pump should have a low capacity.
For AT 400:
Position the rocker switch to "low", see
fig. 5 (A).
For AT 500:
The yellow control light is on, see fig. 6
(A).
3. Set the pump regulator to high capacity if
maximum capacity is desired.
For AT 400:
Switch the rocker switch to "high", see
fig. 5 (B).
For AT 500:
Switch the rocker switch to "2", see fig. 6
(D).The red control light is on, see
fig.6(B).
10
All manuals and user guides at all-guides.com
4
4.1
4.2
Switch off heating:
1. Switch the rocker switch to "0".
The fuel pump stops running.
The control light turns off.
40.020.943 - rev. 04 - 2011

USE

During operation
Caution
Do not operate the heater in hot
weather to burn oil.
Do not burn used oils other than
generated on the premiss of the
owner, unless written
authorization is obtained from the
regulatory authority.
Hot
Do not touch the flue stack or blower
outlet! The flue stack and blower
outlet get hot during operation!
Switching off
Caution
After switching off the heater it will
run for several minutes, until the fuel
on the burner dish is used up. In the
meantime the hot air fan and the
distributor fan keep running. These
fans cool the heater until it has
sufficiently cooled down (after 10 to
30 minutes).
Both fans will stop around the same
time.
AT 400 - 500-US series

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

At 500

Table des Matières