Use; During Operation; Switch Off - THERMOBILE Bio Energy - US Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
4.
Check whether the burner dish is clean and
cold.
5.
Clean the burner dish and the floor of the
combustion chamber if necessary.
6.
Pour 0.2 litre of biodiesel or vegetable oil
onto the burner dish, see fig. 4 (F).
Warning
Never pour biodiesel or vegetable oil
onto a hot burner dish.
The burner dish must be cool!
7.
Form a paper pellet and light it.
8.
Drop the burning pellet on the burner dish.
9.
Close the heat shield.
10. Close the heat distributor.
3.4
Start up
Warning
Never pour biodiesel or vegetable
oil onto a hot burner dish. The
burner dish must be cool and clean!
Do not start the heater if the fan still
runs. The heater is cooling down.
Do not start the heater if excess oil
has accumulated in or near the
heater.
Caution
Do not switch on the convector heater if
there is no fuel, or if the connected fuel
tank is empty.
Caution
Only the following oil types may be used
in the stationary biodiesel or vegetable
oil fired heaters:
Biodiesel
Vegetable oil
Automatic operation:
1.
Switch the rocker switch to "2", see fig. 5 (A).
The combustion air fan starts to run.
When the burner dish has reached the right
temperature, the fuel pump starts running
and the control light is on.
2.
Switch the pump regulator to "low" for the
first 20 to 30 minutes, see fig. 6 (A).
3.
Switch the pump regulator to "high" when the
maximum temperature is reached, see fig. 6
(B).
Manual operation:
1.
Wait 5 minutes for the combustion chamber
to reach the right temperature.
2.
Switch the rocker switch to "1", see fig. 5 (A).
The fuel pump starts running and the control
light is on.
10
3.
Switch the pump regulator to "low" for the
first 20 to 30 minutes, see fig. 6 (A).
4.
Switch the rocker switch to "2" after 20 to 30
minutes.
The pump thermostat starts working.
5.
Switch the pump regulator to "high" when the
maximum temperature is reached, see fig. 6
(B).
4
4.1
4.2
Switch off heating:
1.
Switch the rocker switch to "0".
The fuel pump stops running.
The control light turns off.
40.020.952 - rev. 04 - 2011

USE

During operation

Caution
Do not operate the heater in hot
weather to burn oil.
Do not burn used oils other than
generated on the premiss of the
owner, unless written authorization
is obtained from the regulatory
authority.
Hot
Do not touch the flue stack or blower
outlet! The flue stack and blower outlet
get hot during operation!

Switch off

Caution
After shutting off, the heat distributor fan
will still run. This fan cools the heater
until it has cooled down sufficiently (after
10 to 30 minutes).
The combustion air fan runs as long as
the heat distributor fan.
Bio Energy - US

Publicité

Table des Matières
loading

Table des Matières