English
Description
Drain (water of) condensation from the fuel tank, when
the biodiesel or vegetable oil contains water.
Clean the combustion chamber.
Clean the burner ring.
Clean the combustion chamber and the vaporiser with
a steel brush.
Clean the combustion chamber and the vaporiser with
a steel brush.
Clean the overflow pipe in the floor of the combustion
chamber. See fig. 4 (H)
Check the oil pipes for leakage.
Clean the fuel tank, the supply filter and the fuel filter.
The fuel tank can easily be removed.
Check the combustion air fan and clean if necessary.
Check the hot air fan and clean if necessary.
Clean the flue stack valve in the T-piece, see fig. 8 (A).
The recommended draught is 2 mmwk.
Check the seal between the bottom and the vaporiser
for leakage.
Adjust the pressure on the seal cord, or replace the
seal.
Replace the seal cord in the bottom.
Check the seal ring for leakage.
Adjust the pressure on the seal cord in case of a
leakage.
Clean the heat exchanger.
Clean the flue stack T-piece, see "cleaning the flue
stack valve".
Check the heater's wiring.
Clean the heat exchanger.
Take the heat exchanger apart for a good cleaning.
Hot
Do not touch the flue stack or
combustion chamber!
Do not perform maintenance until the
flue and combustion chamber have
cooled down.
46
Period
Every
12
hours
X
X
X
X
40.020.952 - rev. 04 - 2011
Week-
Month
Every
Annu-
ly
ly
six
ally
month
s
X
X
X
X
X
X
Dealer
X
X
X
X
X
X
Bio Energy - US
Every
two
years