Start-Up Instructions

For initial start-up after heater installation, follow steps
1-5. For normal start-up, set the thermostat above room
temperature or set thermostat selector switch to the
manual position.
1. This heater is wired with a ground connection for your
protection against electrical shock hazard. The heater
must be connected directly to a properly wired and
grounded electrical supply. (Minimum breaker size:
CI230-15 amp, CI500/CI750-20 amp).
2. Set thermostat to desired room temperature or set
thermostat selector switch to the manual position.
3. Position the fuel selector valve as shown for fuel
being used.
This heater is shipped from the factory with the fuel
selector valve in the propane gas (LP)
position. Ensure the fuel selector valve's handle is
properly positioned for the fuel being used.
CI500 / CI750 LABEL SHOWN BELOW
4. This heater has a rocker style selector switch located
on the side of the heater. This switch allows for either
heat mode or ventilate mode (no heat) .
Foreman Ductable Dual Fuel Indirect-Fired Heater
Owner's Manual • Foreman
5. When the switch is set to heat
will be activated in sequence as specific circuits are
checked by the heater controller. If the heater does
not light, and a status light is off, refer to the trouble-
shooting section of this manual.
6. Do not exceed input rating stamped on nameplate or
manufacturer's recommended burner orifice pressure
for size orifice(s) used. Make certain that the primary
air supply to main burner is open and free of dust, dirt
and debris for complete, proper combustion.
A. Heating Mode Operation
a. Open all manual fuel supply valves. Check for gas
leaks using an approved leak detector. Check the gas
selector valve for proper gas.
b. When the selector switch is positioned to heat
and the thermostat is calling for heat, a set of green
lights will illuminate (power ON and thermostat ON).
CI230
• The burner motor has a 60 seconds pre-purge. The
high limit LED and the red status LED on the GeniSys
control board will have a slow steady flash.
CI500/CI750
• The burner motor will pre-purge for 1 minute. The high
limit LED will be flashing during this cycle.
All models
After the pre-purge, the igniter will spark and ignition will
occur. The blower motor has a time delay before operat-
ing (CI230-15 seconds, CI500/CI750-30 seconds). The
thermostat will cycle the heater ON or OFF based upon
temperature setting.
Note: When the thermostat cycles the heater off or the
selector switch is switched to OFF, the blower
motor will continue to run for an additional 90
seconds to cool down the heat exchanger. DO
NOT UNPLUG THE HEATER UNTIL THE COOL
DOWN CYCLE IS COMPLETED.
B. Vent Mode Operation
When the selector switch is positioned to vent
only the main fan light will illuminate. Neither the ignition
cycle nor the burner motor will be initiated. Only the
blower motor will be power. This feature is used typically
when heat is not needed, but air circulation is required.
The heater will not cycle on its thermostat setting. To
discontinue the ventilation feature, position the switch to
midpoint O or heat
.