Start-Up Instructions; Shut-Down Instructions - L.B. White 346 Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

16
Classic Agricultural Animal Confinement Building Heaters
FIG. 11 C
1/2 NPT MALE RIGID END OF
HOSE CONNECTS TO GAS
INLET AT HEATER
3/8 NPT X 5/8 - 18 LHT
HOSE ADAPTER (CONNECT TO HOSE NUT)

Start-Up Instructions

Follow steps 1 - 10 on initial start-up after heater installa-
tion by a qualified gas heater service person. For normal
start-up, simply turn thermostat above room temperature.
The heater will start.
1. Open all manual fuel supply valves and check for gas
leaks using approved leak detectors.
2. Remove the metal cover from the gas control's enclo-
sure.
3. The gas control valve incorporates a manual gas shut
off knob. Position the indicator on the shut off knob to
PILOT.
4. Fully depress the red pilot button located on the
control valve while applying flame to the pilot light.
5. Keep the button depressed for about 30 seconds to
allow the thermocouple to warm up so the pilot stays lit
after you release the pilot button. On new installations
it may take about a minute for the gas to purge out any
air in the pilot line before the pilot lights.
6. Position the knob to ON.
7. Connect the heater's electrical cord to an approved
electrical outlet.
FIG. 12
PILOT
BUTTON
Owner's Manual • Classic
8. Set the thermostat above room temperature. The
POL FITTING (LEFT HAND
heater will light. Reset thermostat to desired room
THREAD) CONNECT TO
temperature.
CYLINDER VALVE
9. Reinstall the protective sheet metal cover over the gas
control valve.
10. Do not exceed input rating stamped on nameplate of

Shut-Down Instructions

If the heater is to be shut down for cleaning, mainte-
nance or repair, follow steps 1 - 5. Otherwise, simply
turn thermostat to off or no heat for standard shut down.
1. Close all manual fuel supply valves.
2. With the heater lit, allow heater to burn off excess fuel
in gas supply hose.
3. Turn the knob on the gas control to OFF.
4. Turn thermostat to off or no heat position.
5. Disconnect the heater from the electrical supply.
KNOB
appliance, or manufacturer's recommended burner
orifice pressure for size orifice(s) used.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

348377379Classique 346Classique 348Classique 377 ... Afficher tout

Table des Matières