Start-Up Instructions - L.B. White Foreman CI230 Manuel Du Propriétaire Et Instructions

Masquer les pouces Voir aussi pour Foreman CI230:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Remote Oil Hook-Up
• The Foreman 230/500 will require kit
500-131261 to be installed for connection to
a remote tank.
• The Foreman 750 will ship ready for
connection to a remote fuel tank. See instructions be-
low.
Foreman 750 connection to a
remote fuel tank.
Materials
• Teflon tape (use on all threaded connections)
• Appropriate pipe fittings to adapt to the 3/8 in. NPT female
threads on the 3/8 in. black iron tee.
Tools
• 5/16 Allen wrench
• Adjustable wrench
Connection to a remote fuel tank
• Close the fuel shut off valve from the on board fuel tank.
• Remove the Allen head plug from the 3/8 in. tee.
• Use the appropriate pipe fittings to reduce the remote hose
fitting to 3/8 in. NPT threads.
• Install the remote hose fitting to the 3/8 in. tee.
• Check ALL connections for tightness.
• Start the heater and check all connections for leaks.
Retighten as necessary to stop any fuel leaks.
Using the onboard fuel tank
• All Foreman Oil heaters are shipped ready to operate from
the onboard tank.
Foreman Ductable Oil Indirect-Fired Heater

Start-Up Instructions

For initial start-up after heater installation, follow steps
1-5. For normal start-up, set the thermostat above room
temperature or set thermostat selector switch to the
manual position.
1. Follow all ventilation and safety information.
2. Fill tank with fuel.
3. This heater is wired with a ground connection for
4. Set thermostat to desired room temperature or set
5. This heater has a rocker style selector switch
6. When the switch is set to heat
7. Do not exceed input rating stamped on nameplate
Owner's Manual • Foreman
your protection against electrical shock hazard. The
heater must be connected directly to a properly wired
and grounded electrical supply. Minimum breaker
size: CI230-15 amp, CI500/CI750-20 amp.
thermostat selector switch to the manual position.
located on the side of the heater. This switch
allows for either heat mode or ventilate mode
(no heat).
lights will be activated in sequence as specific circuits
are checked by the heater controller. If the heater
does not light, and a status light is off, refer to the
trouble shooting section of this manual.
or manufacturer's recommended pump pressure for
nozzle used. Make certain that the primary air supply
to main burner is open and free of dust, dirt and
debris for complete, proper combustion.
13
, three status