Specifications - L.B. White Foreman CI230 Manuel Du Propriétaire Et Instructions

Fournaise gainable bicarburants à chauffage indirect. soutirage de la vapeur des gaz de pétrole liquéfiés ou du gaz naturel
Masquer les pouces Voir aussi pour Foreman CI230:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Foreman Ductable Dual Fuel Indirect-Fired Heater

Specifications

Fuel Type
Maximum Input (Btuh / kWh)
Inlet gas supply pressure acceptable at the inlet
of the heater for purpose of input adjustment
(inches w.c. / kPa)
Burner manifold pressure (inches w.c. / kPa)
Fuel Consumption per hour
Motor Characteristics
Blower Speed (RPM)
Electrical Supply (Volts / Hz /Phased)
Amp Draw
Dimensions (inches/cm) L x W x H
Minimum Safe Distances From
Nearest Combustible Materials
(Feet/ Meter)
Propane Fuel Supply Container
(Feet/Meter)
Minimum Ambient Temperature in Which Heater
May be Used (°F/°C)
Net Weight (lb / kg)
Owner's Manual • Foreman
CI230
L.P. Vapor
Withdrawal
230,000 / 67.4
MAX. 13.5 / 3.36
MIN. 7.0 / 1.7
3.7 / 0.92
10.7 lbs /
4.8 kg
Ball Bearing, 1/2 HP / 373
Watts, 1725 RPM
1725
Starting
32
Continuous
9.0
61 x 26.5 x 41 / 155 x 67 x 104
Top:
Sides:
Rear:
Blower Outlet:
Flue Pipe:
U.S.
Canada
307 / 139.5
CI500
Natural Gas
L.P. Vapor
Withdrawal
500,000 / 146.5
3.6 / 0.90
3.0 / 0.75
230 cu. ft. /
23 Ibs. /
6.5 m3
10.4 kg
Ball Bearing, 1.5 H.P. / 1,119
Watts, 1725 RPM
120 / 60 / 1
14.8
92.5 x 32 x 44.5 / 235 x 81 x 112
3.0 / 0.91
1.0 / 0.30
3.0 / 0.91
6.0 / 1.83
3.0 / 0.91
6.0 / 1.83
10.0 / 3.05
-20 / -29
655 / 297.1
CI750
Natural
L.P. Vapor
Natural
Gas
Withdrawal
Gas
750,000 / 219.8
MAX. 13.5 / 3.36
MIN. 8.0 / 2.0
4.6 / 1.14
2.8 / 0.70
3.4 / 0.85
500 cu. ft.
34.8 lbs. /
750 cu. ft.
/ 14.2 m3
15.8 kg
21.2 m3
Ball Bearing, 2 H.P. /
1,491 Watts, 1725 RPM
1000
240 / 60 / 1
35
12.0
670 / 303.9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Foreman ci500Foreman ci750

Table des Matières