Natural Gas Supply Pressure to 2nd stage regulator
CI230
Regulator
Gas Hose
CI500
Regulator
Gas Hose
CI750
Regulator
Gas Hose
*If the supply inlet pressure to the heater is less than 1/2 psig, a second stage regulator is not required.
Gas Supply Sizing
The vaporization of propane is affected by several factors: the surface area of the container, the liquid level of
propane, temperature surrounding the container, and the relative humidity. All of these factors are specific to a site.
Therefore, a degree of experience and judgement is required to select the proper propane supply. Although experi-
ence is the best guide, the following recommendations can be used as a starting point. The table below is based on
experience in northern climates where cold weather and high humidity are prevalent in the winter. If more or less
favorable conditions prevail at a specific site, adjustments can be made on the basis of experience.
If more than one gas supply container is used per heater, the containers must be connected together by a manifold
to allow vapor withdrawal simultaneously from multiple containers. The manifold system shall be in accordance with
NFPA 58 or CSA B149.1.
Foreman Ductable Dual Fuel Indirect-Fired Heater
2 PSIG
500-132046
500-132136
Contact your local LP Gas dealer
Gas Supply Sizing
Owner's Manual • Foreman
5 PSIG
500-25141
500-25965
500-25141
500-132047
500-132046
15