TROUBLESHOOTING

PROBLEM
Machine will not operate
Brush motor will not operate
Machine does not propel
(Drive model)
Vacuum motor will not operate
FaST Model: FaST System does
not operate or operate correctly
Little or no solution flow
(Conventional Scrubbing)
Tennant T3 (08- -05)
CAUSE
Activation bail not pulled
Discharged batteries
Faulty battery(s)
Loose battery cable
Main fuse blown
Faulty key switch
Scrub head is raised off floor
Battery meter lockout activated
Tripped brush motor circuit breaker
Faulty scrub head (up/down) switch
Faulty activation bail switch
Faulty brush motor or wiring
Worn motor carbon brushes
Main fuse blown
Faulty relay switch
Faulty transaxle motor or wiring
Worn motor carbon brushes
Squeegee is raised off floor
Vacuum motor fuse blown
Faulty vacuum motor or wiring
Worn motor carbon brushes
FaST system switch is not turned on
FaST--PAK supply hose not connected Connect supply hose
FaST Pump fuse blown
Clogged FaST--PAK supply hose or connectors
Empty FaST--PAK carton
Kink in FaST--PAK supply hose
Clogged FaST solution system
Faulty FaST system on/off switch
Faulty pump
Clogged solution tank filter
Clogged orifice/filter screen
Clogged solution tank filter or solution
hose
Clogged solution valve
Solution flow control knob set too low
Loose screw on control knob
Home
Find... Go To..
OPERATION
SOLUTION
Pull activation bail
Charge batteries
Replace battery(s)
Tighten loose cable
Replace fuse
Contact Service Center
Lower scrub head
Recharge batteries
Reset brush circuit breaker button
Contact Service Center
Contact Service Center
Contact Service Center
Contact Service Center
Replace 30 Amp fuse
Contact Service Center
Contact Service Center
Contact Service Center
Lower squeegee
Replace 25 Amp fuse
Contact Service Center
Contact Service Center
Turn on FaST system switch
Replace 7.5 Amp fuse
Soak in warm water to unclog
Replace FaST PAK carton
Undo hose kink
Contact Service Center
Contact Service Center
Contact Service Center
Drain solution tank. remove solution
tank filter, clean and reinstall
Replace orifice/filter screen
(See ANNUAL MAINTENANCE)
Clean solution tank filter or flush out
solution hose
Remove valve and clean
Adjust solution control flow knob
Calibrate knob and retighten screw