Cleaning
Attention!

Maintenance / repair

Attention!
Attention!
Note

Dismantling and disposal

>
Empty the pump, the hose and the fittings prior to dismantling.
>
Collect environmentally harmful substances and liquids in appropriate containers
and dispose of them in an environmentally sound manner.
>
Dispose of scrap material and parts that cannot be repaired or reused in an
environmentally sound manner
18 / 32
Clean pump, motor and mains connection only outside the
hazardous area.
Clean pump when changing container or product.
Rinse the pump with an appropriate detergent.
Pump and hose must be resistant to the cleaning agent.
Do not use flammable liquids.
Observe the safety instructions.
Only the manufacturer or an authorized repair shop may carry
out repairs on explosion-proof motors or pumps.
Regularly check all motors in accordance with the legal/country-
specific requirements and accident prevention regulations (in
Germany, e.g. DGUV Vorschrift 3).
Regularly check motor, cable, pump and hose on operational
safety.
Always replace defective mains connection cables.
Only trained electricians may carry out changes to the mains
connection.
Empty pump, hose and fittings before maintenance / repair.
Totally open the fittings for emptying.
On maintenance / repair of the pump, remove the motor from
the pump.
Regularly check the hose clamps or hose holders for firm
seating.
Always replace defective parts.
Only use genuine spare parts.
Returns and repairs are processed via our homepage
(RMA form under "Service").
www.flux-pumps.com