Electrical Data
Absorbed power (¹)
Absorbed power (²)
Absorbed power (³)
4
Absorbed power (
)
5
Absorbed power (
)
Circulating pump absorbed power (P1)
Circulating pump absorbed power (P2)
Circulating pump absorbed power at max. speed (PS1)
Electrical power supply
Auxiliary power supply
Circulating pump absorbed current (P1)
Circulating pump absorbed current (P2)
Circulating pump absorbed current at max. speed (PS1)
Nominal current (¹) (without circulating pump)
Nominal current (²) (without circulating pump)
Max. current (without circulating pump)
Starting current
Dimensions
Width (L)
Height (H)
Depth (P)
Water connections
(1) In the following conditions: water temperature at condenser
inlet/outlet 30-35°C; chilled water outlet temperature 7°C; temperature
differential at evaporator 5°C.
(2) In the following conditions: water temperature at condenser
inlet/outlet 40-45°C; evaporator inlet water temperature 10°C at same
flow rate of summer operation.
(3) In the following conditions: water temperature at condenser
inlet/outlet 35-30°C; evaporator inlet water temperature 10°C at same
flow rate of summer operation.
(4) In the following conditions: water temperature at condenser
inlet/outlet 30-35°C; evaporator inlet/outlet water temperature 0/-3°C
with 30% glycol.
(5) In the following conditions: water temperature at condenser
inlet/outlet 30-35°C; chilled water outlet temperature 18°C; temperature
differential at evaporator 5°C.
(6) Total sound power level in dB(A) measured in accordance with
standard ISO 3744 and Eurovent 8/1. Noise data refers to pumpless
units.
(*) Energy indices for standard set-ups calculated in accordance with
standard EN 14511:2004; in the conditions prescribed by the Financial
Act (D.M. 6 August 2009) for the Italian market.
E.S.E.E.R. European Seasonal EER (European average seasonal
energy efficiency).
E.S.E.E.R. + with AdaptiveFunction Plus logic.
Note:
The calculations for the E.E.R. and C.O.P. indices do not take into
account pump consumption (unless stated otherwise).
Power consumption data does not take into account pump consumption
(unless stated otherwise).
ALLEGATI / ENCLOSED DOCUMENTS / ANNEXES / ANLAGEN / ANEXOS
115
118
kW
3.60
3.88
kW
3.87
4.31
kW
3.19
3.44
kW
3.20
3.50
kW
3.49
4.04
kW
0.40
0.40
kW
0.55
0.55
kW
0.40
0.40
V-ph-Hz
V-ph-Hz
A
1.5
1.5
A
2.5
2.5
A
1.5
1.5
A
6.1
6.4
A
7.1
7.6
A
9.4
10.2
A
64
64
mm
700
700
mm
1140
1140
mm
560
560
Ø
H
104
122
125
230
4.75
5.44
7.09
5.48
6.19
7.89
4.34
4.92
6.45
4.10
4.80
6.50
4.99
5.81
6.88
0.40
0.75
0.75
0.37
0.37
1.12
0.75
0.75
0.75
400-3+N-50
230-1-50
1.5
1.9
1.9
3
3
2.2
1.85
1.85
1.85
9.3
9.8
12.2
10.7
11.1
14.2
14.3
15.2
18.8
101
95
74
700
700
700
1140
1140
1140
780
780
780
1-½"G M
240
8.65
9.92
7.89
7.70
9.21
0.75
1.12
0.75
1.9
2.2
1.85
14.9
17.5
24.2
87
700
1140
780