Installation and Connection
Overview of device connections
DE
EN
Connections on top of device
FR
IT
ES
PT
NL
SV
FI
DA
NO
EL
Fig. 6: Overview of connections on top of device
CZ
1
WiFi antenna
2/3/4 Current sensors (J301),
HU
Current sensors (J300),
Current sensors (J200)
PL
5
Voltage measurement (J400),
voltage range: 100 V — 240 V (AC)(L-N)
HR
SR
SK
SL
ET
LT
LV
RO
BG
MK
28
Connections on underside of device
Fig. 7: Overview of connections on underside of device
6
USB1
7
USB2
8
ETH 0
9
ETH 1
10
RS485/CAN (J1000) (not assigned)
11
Power supply (J102), 24 V (DC)
12
Relay (J900) (not assigned)
13
Relay (J901) (not assigned)
f Refer to chapter "Overview of connectors" on
page 28.
Installation and Connection
Overview of connectors
The overview of device connections (Fig. 6, Fig. 7)
shows the connection position of connectors used
for current sensors, voltage sensors, relay contacts
and communication. The diagram illustrates
the position of the pins for each type of connector.
The tables show the pin assignment with
corresponding signal.
f Refer to chapter "Overview of device
connections" on page 28.
Connector for current measurement
Information
It is essential to note the connection positions of
the current sensors, the type of current sensor,
their phase assignment and the rated current of the
phase fuse, as you will be asked for this information
later on when configuring the energy manager
(home installation).
Parameter
Value
Connector
J200/J300/J301
Manufacturer
Phoenix Contact
Socket part number
1786853
Connector part number
1790124
Overview of J200/J300/J301 connectors
The connectors of the current sensors (J200, J300,
J301) are identical and can be connected to any of
the connections provided (Fig. 6 - 2/3/4).