Drive Assembly Removal And Installation - Pentair IntelliFlo VF Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 138
56

Drive Assembly Removal and Installation

To remove the IntelliFlo drive and control panel from the motor assembly:
1. Make sure all electrical breakers and switches are turned off before removing the drive.
2. Disconnect the communication cable from the pump.
3. Open the control panel cover.
4. Remove the three Phillips head screws securing the drive to the motor assembly as shown.
CAUTION: TO AVOID ELECTRICAL HAZARD, DO NOT REMOVE THE TAMPER
PROOF SCREWS (QTY 4) FROM THE MOTOR ASSEMBLY
5. Lift up the drive assembly and remove it from the motor adapter located on top of the motor assembly.
Note: Be careful not to remove the gasket between the drive and motor, it is critical in keeping
moisture out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a
damaged or missing gasket.
To install the IntelliFlo drive assembly onto the motor assembly:
1. Make sure all electrical breakers and switches are turned off before removing the drive.
2. Ensure that the gasket between the drive and motor is in place. It is critical in keeping moisture out
of the drive and motor. Replace the gasket if damaged. Do not reassemble with a damaged or missing
gasket.
3. Align the drive assembly with the motor adapter and seat the drive on the motor assembly.
4. Secure and tighten the drive assembly with the three Phillips head screws.
Phillips head screw
Do not remove these
Orange motor post
caps (QTY. 3)
IntelliFlo VF Installation and User's Guide
screws
Phillips head screws
Gasket
Adapter connector

Publicité

Table des Matières
loading

Table des Matières