Features Menu (Continued)

4. To change a setting, press the Left and Right arrows to select which digit to modify, then use the
Up and Down arrows to change the selected digit.
5. When you are done, press the Enter button to save the changes. To cancel any changes, press the
Escape button to exit the setting without saving.

Feature 3-9 Operation

Feature 3-9 function as part of the filter cycles programmed in the Filter menu and IntelliFlo must be in
Filter Mode for Feature 3-9 to operate. Unlike Feature 1(2), Feature 3-9 cannot be operated on an "on
demand" basis. If Enabled is selected in the Feature 3-9 "Activation" setting, Feature 3-9 will start and
stop at the times programmed in the Feature 3-9 settings menu whenever IntelliFlo is in Filter Mode. If
Disabled is selected in the "Activation" setting, IntelliFlo will not run Feature 3-9.
The parameters you program for features Feature 3-9 supercede the filter cycle parameters you
programmed for Filter Mode
programmed for Filter Mode, until the time of day you programmed as the "Start" time for Features 3-9.
At that time, IntelliFlo will switch to the flow rate you set for Features 3-9, and will operate at those
parameters until the "Stop" time you entered for the feature. IntelliFlo will then resume the interrupted
filter cycle at the point it left off, and will recalculate the the time it needs to run at the filter cycle flow
rate to in order to complete the filter cycle (See page 31 for more information on using Feature 3-9 in
conjunction with Filter Mode.).
Flow
10 m
3
/h
8:00
Original Filter Cycle w/No Timed Feature
IntelliFlo VF Installation and User's Guide
in the Filter settings
Filter
Cycle
Time
22:00
menu. IntelliFlo will operate at the parameters you
Flow
Feature 3
20 m
3
/h
10 m
3
/h
Filter
Cycle
8:00
18:00
New Flow/Time Optimized Filter Cycle
Time
19:00
21:00