A.2 Technical Data - Siemens SITRANS FUS1010 IP65 NEMA 4X Instructions De Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A.2
Technical Data
Transmitter
● Operating Temperature Range: -18°C to 60°C (0°F to 140°F)
● Storage Temperature Range: -20°C to 93°C (-4°F to 200°F)
Degree of Protection
● Wall mount enclosure: IP65 (NEMA 4X)
● Wall mount explosionproof: IP66 (NEMA 7)
Input
● Flow Range: ± 12 m/s (± 40 ft/s), bidirectional
● Flow sensitivity: 0.0003 m/s (0.001 ft/s), flow rate independent
Accuracy
● Calibratable accuracy: ± 0.15% to 0.3% of flow, depending on version
● Batch repeatability: ± 0.05% of flow, maximum
● Zero Drift: 0.0003 m/s (0.001 ft/s), with ZeroMatic path active
● Data refresh rate; 5 Hz (80 Hz output for flow rate available on special order)
Power Supply
● IP65 (NEMA 4X) and IP66 (NEMA 7) Wall Mount - 90 to 240 VAC @ 50 or 60 Hz 30 VA /
Sensor
● Type: Nonintrusive, externally mounted
● Temperature Range: -40°C to +120°C (-40°F to +250°F)
Dimensions
● 23.6 cm (9.31 in) x 28.7 cm (11.31 in)
● Net weight: 4.1 kg (9.0 lbs.) max
Liquid Temperature
● Standard: -40°C to +121°C (-40°F to +250°F)
● Optional: -40°C to +232°C (-40°F to +450°F)
FUS1010 IP65 NEMA 4X & IP66 NEMA 7 Quick Start
Operating Instructions, 07/2014, A5E03086486-AD
9 to 36 VDC, 12 Watts
Appendix

A.2 Technical Data

73

Publicité

Table des Matières
loading

Table des Matières