Mounting Temperature Sensors - Siemens SITRANS FUS1010 IP65 NEMA 4X Instructions De Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connecting
3.5 Sensor Installation
2. Slide sensor into a mounting frame back end first aligning the angled edge of the sensor
with the angled edge of the mounting frame. Keep sensor from making contact with the
pipe until it butts up against the mounting frame stop. Push sensor down to mate with
pipe.
3. Tighten the sensor clamping screws to hold the sensor firmly in place.
for the other sensor.
4. If installing a temperature sensor proceed to Mounting Temperature Sensor (Page 42). If
not, proceed to Sensor Wiring (Page 45).
3.5.3

Mounting Temperature Sensors

Temperature is used to normalize the liquids sonic velocity in order to properly determine
interfaces and for density determination. Temperature sensors are available in clamp-on
style or in insert (Thermowell) style. Refer to the table below. Both styles incorporate 1000
ohm platinum RTD's for high precision.
Table 3- 3
Temperature Sensors
Description
Standard clamp-on RTD
Submersible clamp-on RTD (not for FUP1010 or FUE1010
Standard clamp-on RTD pair for FUE1010 energy system
Insertion style RTD (size 1): 140mm (5.5 in)
Insertion style RTD (size 2): 216mm (8.5 in)
Insertion style RTD (size 3): 292mm (11.5 in)
Insertion style RTD (size 4): 368mm (14.5 in)
Insertion style RTD pair (size 1) for FUE1010, 140mm (5.5
in)
Insertion style RTD pair (size 2) for FUE1010, 216mm (8.5
in)
Insertion style RTD pair (size 3) for FUE1010, 292mm (11.5
in)
Insertion style RTD pair (size 4) for FUE1010, 368mm (14.5
in)
42
Part Number
7ME39501TA00
7ME39501TB00
7ME39501TA10
7ME39501TJ00
7ME39501TJ01
7ME39501TJ02
7ME39501TJ03
7ME39501TJ10
7ME39501TJ11
7ME39501TJ12
7ME39501TJ13
FUS1010 IP65 NEMA 4X & IP66 NEMA 7 Quick Start
Operating Instructions, 07/2014, A5E03086486-AD
Repeat procedure