5.
Turn the pressure governor in anti-clockwise direction to the lowest position, up
to the mechanical stop.
6.
Open the pressure relief valve and check on the pressure gauge that the system is
depressurised and the display shows „0 bar".
Note: read Section „Designation of components D"
7.
Place the bypass hose in an empty bucket and open the water valve.
8.
Switch on the Airless device at the On/Off switch, slowly turn the pressure regu-
lator to „9 o'clock position" (the motor slowly starts) and rinse until clear water
escapes from the bypass hose.
9.
Hold the Airless gun into and at the inner edge of the bucket with the collected
waste water, unlock the trigger lock on the Airless gun and pull and hold the trig-
ger on the gun.
10.
Now close the pressure relief valve and water now flows through the Airless hose
and the gun. Now rinse until clear water escapes. Change between the two cir-
cuits by opening and closing the pressure relief valve.
Note: Read in Section „Designation of components D+E"
11.
Switch off the device, open the pressure relief valve and the housing of the
device filter and clean it.
WARNING:
Clean the device as follows if a water connection is not available:
Original instruction
148