6.0 CLEANING, MAINTENANCE, AND STORAGE
6.1
The Rope Grab and Rope should be cleaned separately in lukewarm water with a small amount of neutral
detergent added. After washing rinse thoroughly with clean water and allow to dry naturally away from
direct sunlight. Cleaning and drying should be carried out immediately after every use in a marine
environment.
Store in a clean, dry environment avoiding extremes of temperature, corrosive fumes or chemical
substances. If the Rope and/or Rope Grab comes into contact with chemicals refer to chemical data sheets
and/or the manufacturer.
When the Rope and Rope Grab are used in extremely cold weather, be aware if there is a possibility of
water/ice coming into contact with the moving parts of the Rope Grab. Ensure that the cam/clamp teeth are
free from ice.
Ropes should not be stored in direct sunlight or where they may be affected by any source (e.g. radiators).
Storage and room humidity should be 60% and 25°C approximately. Ropes should not come into contact
with any chemicals and should be removed from service if they come into contact with chemicals outside the
PH range of 5.5 – 8.5.
6.2
Replacement parts and additional maintenance and servicing procedures must be completed by an
authorized service center. An authorization and return number must be issued by Capital Safety.
6.3
Clean and store all system components according to the manufacturers' instructions.
7.0 SPECIFICATIONS/PERFORMANCE DATA
7.1
SPECIFICATIONS:
•
Rope Grab Weight: 0.175 kg (0.39 lbs.)
•
Rope Grab Dimensions (including pivot pin): 89 x 63 x 62 mm (3.5 x 2.5 x 2.4 in.)
•
Rope Type: 12.5 mm (
•
Rope Weight: 87.2 g/m ± 10%
7.2
PERFORMANCE DATA:
•
Arrest Force: Designed for 6 kN (1,349 lbf.) maximum arresting force.
•
Maximum Capacity:
- AC4000 and AC4001: 100kg (220 lbs)
- AC4002 vertical use: 140kg (308 lbs)
- Roof top fall arrest use: 100kg (220 lbs)
•
Applicable Standards: EN 352-2:2002, EN 358:2000, EN 1891:1998
low stretch Kernmantle
~1/2" in.)
8