Type 2000, 2006, 2012
2030, 2031, 2032, 2033
Electricalpositionfeedbackindicator
10.2.2 Installation and commissioning
→
Screw the adapter (2) onto the actuator instead of the trans-
parent cap (see "Image 11").
→
Screw the electrical position feedback indicator (1) into the
adapter (2), observing the note in chapter "10".
10.3 Actuator sizes 175, 225 (Ø in mm)
Screw-in
base
Actuator
Image 12: Actuator sizes 175, 225 (Ø in mm) with electrical
position feedback indicator
WARNING!
Risk of injury and functional failure due to parts jumping out
or slipping.
The actuators contain preloaded springs that can jump out or slip
if not opened properly.
▶ The actuators Ø 175 mm and 225 mm may only be opened by the
manufacturer.
Required parts
1 Electrical
position feedback
indicator with device
socket
2 Adapter
3 Spindle cover cap
10.3.1 Work before installation
→
Interrupt the supply of the medium flow.
→
Drain the valve body.
→
Move the actuator to the upper piston position. To do this, apply
compressed air to the lower piston chamber via the lower pilot
air port (control functions A and I).
→
Unscrew the transparent cap from the actuator cover (6)
(observe the safety instructions in chapter "10" on page 19!).
→
Unscrew the position indicator (yellow screw cap) by hand.
→
Screw the spindle cap (3) onto the end of the spindle instead of
the
position indicator (AF14).
→
Then interrupt the supply of pilot air.
10.3.2 Installation and commissioning
→
Screw the adapter (2) onto the actuator instead of the trans-
parent cap (see "Image 12").
→
Screw the electrical position feedback indicator (1) into the
adapter (2), observing the note in chapter "10".
English
21